Pr30 – minimum length, Pr31 – minimum height, Pr32 – maximum length – MagTek MICRImage User Manual
Page 53: Pr33 – maximum height, Pr34 – micr threshold
![background image](/manuals/413788/53/background.png)
Section 6. Property Commands
45
BC5 SO<CR>
to decode the two barcode 128 symbols defined in PR20.
TI F3 S8<CR>
to send the current image named IMAGE.TIF containing the tag “MY TAG” to the
auxiliary port using the YMODEM protocol.
The limit for each of these properties is 45 characters.
PR30 – Minimum Length
Sets the minimum length for a document in pixels. A value of zero disables this limit. If the scanned
document is shorter than this length, an error is returned.
PR30=1175<cr>
PR31 – Minimum Height
Sets the minimum height for a document in pixels. A value of zero disables this limit. If the scanned
document is less than this height, an error is returned.
PR31=530<cr>
PR32 – Maximum Length
Sets the maximum length for a document in pixels. A value of zero disables this limit. If the scanned
document is longer than this length, an error is returned.
PR32=1250<cr>
PR33 – Maximum Height
Sets the maximum height for a document in pixels. A value of zero disables this limit. If the scanned
document is higher than this height, an error is returned.
PR33=560<cr>
PR34 – MICR Threshold
Sets the MICR line noise threshold. Range 0 – 255. The useful range is approximately 8 – 25. Lower
values will allow lower amplitude characters to be read but also will make reading more susceptible to
errors caused by EMF noise. Default is 15.
PR34=15<cr>