Section 10. Utilities
bytes. If Offsets are not used, Auto Detect may be chosen and the file 
will be processed correctly. 
10.3.3.1.2 File Offset/Options
Start Offset
None
Select his check box to start reading the input file from the beginning.
Last Count
Each time Split runs a parameter file, it keeps track of the number of bytes 
it read from the input file and saves this information in the parameter file. 
Split can then start where it last left off. This is done by clicking the 
Offsets button and selecting the Last Count option. This feature may be 
used to process only the new data from a file in which new data are being 
appended periodically to the data file. 
When using the Last Count option, if the Start and Stop 
Conditions are specified, they must exist in the newly 
appended data or Split will never begin execution. 
CAUTION
Because Last Count keeps track of the number of bytes in 
the file, if you delete data from the beginning of a file, Last 
Count will not work properly. 