2 — INSTALLATION & WIRING:
Controller
nuts required for the M8 bolts. The maximum bolt insertion depth below
the surface of the bus bar is 1.3 cm (1/2"). Bolt shafts exceeding this length
may damage the controller. The torque applied to the bolts should not exceed
16.3 N·m (12 ft-lbs).
Two 1/4" quick connect terminals (
S1
and
S2
) are provided for the con-
nections to the motor field winding.
WIRING: Standard Configuration
Figure 3 shows the typical wiring configuration for most applications. For
walkie applications the interlock switch is typically activated by the tiller,
and an emergency reverse switch on the tiller handle provides the emergency
reverse signal.
For rider applications the interlock switch is typically a seat switch or
a foot switch, and there is no emergency reverse.