Wesley BCT-6200-6SA User Manual

Page 58

Advertising
background image

Curtis 1243

GEN

2 Manual,

Rev. B

50

3 — PROGRAMMABLE PARAMETERS:

BDI

BDI% will automatically reset to 100%. The reset voltage value can be set from
the programmed Full Volts value up to 3.00 VPC, in 0.01 VPC increments.

BATTERY ADJUST
The battery adjustment parameter is used to adjust the BDI algorithm to
compensate for battery capacity. Higher capacity batteries can spend more
time below the Full Volts setting before beginning to lose charge. The battery
adjustment parameter sets the number of seconds of droop required before
the battery state of charge is decremented by 1%. It is adjustable from 0.1 to
20.0 seconds.

BDI DISABLE
The BDI disable parameter, when programmed On, limits the vehicle’s maxi-
mum speed to the BDI Limit Speed when the battery state-of-charge is 0%.

BDI LIMIT SPEED
The BDI limit speed parameter sets the vehicle’s maximum allowed speed when
the BDI disable parameter is programmed On and the battery state of charge
is 0%. The BDI limit speed is adjustable from 0 to 100% of drive output.

If the BDI disable parameter is programmed Off, the BDI limit speed

will not be in effect.

Table 5 STANDARD BATTERY VOLTAGES

FOR FLOODED LEAD ACID AND SEALED MAINTENANCE-FREE BATTERIES

24V BATTERY

36V BATTERY

PARAMETER

FLOODED

SEALED

FLOODED

SEALED

Full volts

24.5 V

24.5 V

36.7 V

36.7 V

(2.04 Ч 12)

(2.04 Ч 12)

(2.04 Ч 18)

(2.04 Ч 18)

Empty volts

20.9 V

22.9 V

31.3 V

34.4 V

(1.74 Ч 12)

(1.74 Ч 12)

(1.91 Ч 18)

(1.91 Ч 18)

Reset volts

25.2 V

25.2 V

37.8 V

37.8 V

(2.10 Ч 12)

(2.10 Ч 12)

(2.10 Ч 18)

(2.10 Ч 18)

Note: To convert VPC to the actual Full, Empty, or Reset voltage,

multiply the VPC by 12 for 24V systems or by 18 for 36V systems.

Advertising