2 — INSTALLATION & WIRING:

Controller

Standard Power Wiring

Motor armature wiring is straightforward, with the armature’s A1 connection
going to the controller’s

B+

bus bar and the armature’s A2 connection going

to the controller’s

M-

bus bar.

The motor’s field connections (S1 and S2) are less obvious. The direction

of vehicle travel with the forward direction selected will depend on how the
motor’s S1 and S2 connections are made to the controller’s two field terminals
(

S1

and

S2

) and how the motor shaft is connected to the drive wheels through

the vehicle’s drive train.

CAUTION:

The polarity of the

S1

and

S2

connections

will affect the operation of the emergency reverse feature. The forward and
reverse switches and the

S1

and

S2

connections must be configured so that

the vehicle drives away from the operator when the emergency reverse button
is pressed.

Standard Control Wiring

Wiring for the input switches and contactors is shown in Figure 3; the pins are
identified on page 6. In the standard wiring configuration, the auxiliary driver
at Pin 8 is used to drive an electromagnetic brake.

The main contactor coil must be wired directly to the controller as shown

in Figure 3. The controller checks for welded or missing contactor faults and
uses the main contactor coil driver output to disconnect the battery from the
controller and motor when specific faults are present. If the main contactor
coil is not wired to Pin 4, the controller will not be able to open the main
contactor in serious fault conditions and the system will therefore not meet
EEC safety requirements.