68

Program Menu Notes

1

Throttle types (for detail, see Throttle Wiring in Section 2)

Type 1: 5kΩ–0 potentiometers

Type 2: single-ended 0–5V, 3-wire pot, current source, and electronic throttles

Type 3: 0–5kΩ potentiometers

Type 4: wigwag 0–5V and 3-wire pot throttles

2

HPD types (for detail, see Section 3: Programmable Parameters, page 41)

Type 0: no HPD

Type 1: HPD fault unless KSI and interlock inputs are received before a

throttle request >25%

Type 2: HPD fault unless KSI input is received before a throttle request >25%

3

SRO types (for detail, see Section 3: Programmable Parameters, page 42)

Type 0: no SRO

Type 1: SRO fault unless KSI + interlock inputs are received before a direction

is selected

Type 2: SRO fault unless KSI + interlock inputs (in that order) are received

before a direction is selected

Type 3: SRO fault unless KSI + interlock + forward inputs received in that

order; a reverse input can be received at any point in the sequence.

4

Auxiliary driver types (for detail, see Table 3, page 30)

6 — PROGRAMMER MENUS: