Fig. 15, Curtis 1243, 2 manual – Wesley BCT-6200-6SA User Manual
Page 41: 3 — programmable parameters
Curtis 1243
GEN
2 Manual,
Rev. B
33
3 — PROGRAMMABLE PARAMETERS:
Throttle Parameters
Fig. 15
Effect of adjusting
the Throttle Deadband
parameter.
Throttle Type 3 (0–5k
Ω)
Throttle Type 2 (0–5V, single-ended)
Throttle Type 1 (5k
Ω–0)
Throttle Type 4 (0–5V, wigwag)
5V
0
0.2V
(0
Ω)
40% Deadband
10% Deadband
0% Deadband
0.5V
(450
Ω)
1.4V
(2.0k
Ω)
Notes: Voltages shown are at the pot wiper relative to B-.
For throttle types 1 and 3, the deadband points are
defined in terms of the nominal 5k
Ω pot resistance.
Using a pot of greater or lesser resistance will give
different values for the deadband points.
Throttle Max parameter set at 100%.
3.3V
(5.0k
Ω)
5V
0
0.2V
40% Deadband
10% Deadband
0% Deadband
0.7V
2.1V
5V
0
3.3V
(5.0k
Ω)
40% Deadband
10% Deadband
0% Deadband
3.0V
(4.5k
Ω)
2.1V
(3.0k
Ω)
0.2V
(0
Ω)
3.3V
(5.0k
Ω)
3.3V
(5.0k
Ω)
0.2V
(0
Ω)
0.2V
(0
Ω)
KEY
100%
Neutral
Deadband
Controller
Output
0%
5V
0
0.5V
40% Deadband
10% Deadband
0% Deadband
2.7V
3.3V
4.5V
4.5V
4.5V
2.5V
0.5V
0.5V
2.3V
1.7V