4 — INSTALLATION CHECKOUT

If the switch wiring is correct, turn off the controller, disconnect the
battery, and exchange the motor’s field connections (

S1

and

S2

) on the

controller. The motor should now turn in the proper direction.

The motor should run proportionally faster with increasing throttle.

If not, refer to Section 7.

CAUTION:

The polarity of the

S1

and

S2

con-

nections will affect the operation of the emergency reverse feature. The
forward and reverse switches and the

S1

and

S2

connections must be

configured so that the vehicle drives away from the operator when the
emergency reverse button is pressed.

5. Select the Monitor menu, and scroll down to observe the status of the

forward, reverse, interlock, emergency reverse, and mode switches. Cycle
each switch in turn, observing the programmer. The programmer should
display the correct status for each switch.

6. Verify that all options, such as high pedal disable (HPD), static return

to off (SRO), and anti-tiedown are as desired.

7. On walkies, verify that the emergency reverse feature is working cor-

rectly (i.e., press the emergency reverse button, and confirm that the
wheels turn in the proper direction to drive the vehicle away from the
operator).

If you have the optional emergency reverse check wiring, verify the

checking circuit. Apply throttle so that the drive wheel spins. While
continuing to apply throttle, temporarily disconnect one of the emer-
gency reverse wires. The drive wheel should come to a stop and a fault
should be indicated. Be sure to reconnect the emergency reverse wire
after completing this test of the checking circuit.

C A U T I O N