Wesley BCT-6200-6SA User Manual

Page 47

Advertising
background image

Curtis 1243

GEN

2 Manual,

Rev. B

39

3 — PROGRAMMABLE PARAMETERS:

Field Parameters

FIELD MAP
The field map defines the relationship between armature current and field current
under steady-state drive conditions. The shape of the field map is determined
by the programmed Field Min, Field Max, Field Map, Field Map Start, and
M1-M4 Drive C/L settings.

As shown in Figure 20, the field map parameter adjusts the field current

at the Field Map Midpoint, which is located halfway between the programmed
Field Map Start and the programmed M1-M4 Drive C/L. With the field map
parameter set at 50%, the motor’s field current increases linearly with increasing
armature current—thus emulating a series wound motor.

Fig. 20

Field current

relative to armature
current, with field map
parameter set at 50%
and 20%.

ARMATURE CURRENT

FIELD CURRENT

Field Map Start

Field Map Midpoint

100%

Drive C/L

0

0

Field Min

Field Max

Field Map

(50%)

ARMATURE CURRENT

FIELD CURRENT

Field Map Start

Field Map Midpoint

100%

Drive C/L

0

0

Field Min

Field Max

Field Map

(20%)

Decreasing the field map parameter reduces the field current at a given

armature current. As the field current is reduced, the motor will be able to
maintain speeds closer to the maximum speed value as its load increases;
however, the motor’s capability to produce torque at these higher speeds will
decrease. With the Field Map reduced to 20%, the field current at the Field
Map Midpoint will exceed Field Min by 20% of the range between Field Min
and Field Max.

The field map parameter is tuned as part of the vehicle performance

adjustment process (Section 5).

Advertising