Wesley BCT-6200-6SA User Manual
Page 77
Curtis 1243
GEN
2 Manual,
Rev. B
69
1243
GEN
2 MONITOR MENU
THROTTLE %
Throttle reading, as % of full throttle
FIELD CURRENT
Motor field current, in amps
ARM CURRENT
Motor armature current, in amps
FIELD PWM
Motor field applied duty cycle, as %
ARM PWM
Motor armature applied duty cycle, as %
BDI %
Battery state of charge, as % of full charge
LOAD VOLTAGE
Load sensor voltage, in volts
BATT VOLTAGE
Battery voltage across the capacitors, in volts
MOT RES
x
10
m
Ω
Motor field winding resistance, in 10-milliohm units
HEATSINK TEMP
Heatsink temperature, in °C
TOT SRVC X25
Total service hours, multiple of 25
+TOT SRVC
Total service hours, in hours
TRAC SRVC X25
Total traction hours, multiple of 25
+TRAC SRVC
Total traction hours, in hours
FORWARD INPUT
Forward switch: on/off
[neutral switch for Type 4 throttle]
REVERSE INPUT
Reverse switch: on/off
MODE INPUT A
Mode Select 1 switch: on/off
MODE INPUT B
Mode Select 2 switch: on/off
INTERLOCK
Interlock switch: on/off
EMR REV INPUT
Emergency reverse switch: on/off
MAIN CONT
Main contactor: on/off
AUX DRIVER
Auxiliary driver: on/off
SYS MODE
Operating mode: 0–6
[0=neutral, 1=drive, 2=regen, 3=regen taper, 4=field reversal,
5=aux driver Off, 6=disable (major fault)]
6 — PROGRAMMER MENUS:
Test/Monitor Menu
Note: If you are using the older 1307 programmer,
the 1311’s Monitor Menu is called the Test Menu.