Redundant twisted pair ports, Table 2. twisted pair ports matched with sfp slots – Allied Telesis x600-48Ts/XP User Manual

Page 27

Advertising
background image

x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide

27

Redundant Twisted Pair Ports

Four of the twisted pair ports on the x600-24-Ts and x600-24-Ts/XP
switches are paired with SFP slots. The twisted pair ports are identified
with the letter “R” for “Redundant” as part of their number on the faceplate
of the unit. The ports and slots are listed in Table 1.

Follow these guidelines when using these ports and slots:

ˆ

Only one port in a pair can be active at a time. It can be either the
twisted pair port or the corresponding SFP module.

ˆ

The twisted pair port is the active port when its SFP slot is empty, or
when the SFP module is installed but has not established a link to the
end node.

ˆ

The twisted pair port automatically changes to the redundant status
mode when the SFP module establishes a link with the end node.

ˆ

The twisted pair port automatically transitions back to the active status
when the link is lost on the SFP module.

ˆ

In nearly all cases, the twisted pair port and the SFP module share the
same configuration settings, including port settings, VLAN
assignments, access control lists, and Spanning Tree Protocol
settings.

ˆ

An exception to the shared settings is port speed. If you disable Auto-
Negotiation on the twisted pair port and set the speed and duplex
mode manually, the speed reverts to Auto-Negotiation when the SFP
module establishes a link with the end node.

Table 1. Twisted Pair Ports Matched with SFP Slots

Models

Ports and Slots

x600-24Ts and
x600-24Ts/XP

21R with SFP slot 21
22R with SFP slot 22
23R with SFP slot 23
24R with SFP slot 24

Advertising
This manual is related to the following products: