Stack member failure and recovery, Table 11. stacking led functions – Allied Telesis x600-48Ts/XP User Manual

Page 49

Advertising
background image

x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide

49

Table 10. Stacking LED Functions

Running QoS within a VCS stack

In general you can apply the same principles when configuring QoS on a
VCS stack as you would for single switch; however there are a few specific
changes that you will need to make. See the AlliedWare Plus Software
Reference
more information on this topic.

Stack Member

Failure and

Recovery

Management IP Addresses

A single virtual MAC address, from the current Master, will be used as the
stack MAC address. If the stack master fails, the stack MAC address
changes to reflect the new master's MAC address. If the stack MAC
address does change, ARP tables of devices on the network will update to
reflect the change in MAC address via gratuitous ARP.

LED

State

Description

STACK LEDs

MSTR

Green ON The switch is the Stack Master.

Green OFF The switch is acting as a stack back-up

member.

1- L/A

Green ON Link on stacking port 1 is active.

Green
Flashing

Indicates traffic flowing through stacking port 1

Green OFF Link on stacking port 1 is inactive.

2- L/A

Green ON Link on stacking port 2 is active.

Green
Flashing

Indicates traffic flowing through stacking port 2.

Green OFF Link on stacking port 2 is inactive.

PRES

Green ON VCS Stacking Module (AT-StackXG) or

Loopback Module (AT-LBM) has been
inserted, i.e. is PRESENT.

STATUS LEDs

MASTER

Green ON The switch is the Stack Master.

Green
Flashing

When the show stack indicator command is
activated, this LED will flash with a pattern that
indicates the stack member ID of the switch.

Advertising
This manual is related to the following products: