Table 10. state change table – Allied Telesis x600-48Ts/XP User Manual

Page 43

Advertising
background image

x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide

43

Table 9. State Change Table

1. The fallback action on a slave is first to run the fallback config script.

Where there is no fallback script, the switch will disable all its switch
ports.

2.

The stack member assumes the role of stack master. In specific situations this
condition could result in a stack containing two masters. This would present problems
with network management and the control of links that were previously aggregated.

3.

The following situation will apply to a switch that has been removed from the stack by
the using the “no stack enable” command

a.

The switch will be unaware of further faults within the stack it was previously a
member of.

b.

Should this switch then be powered down, all links previously shutdown (as a
result of running the “no stack enable command”) will remain down.

4.

If the slave’s ports are still up, this may cause downstream switches with trunked ports
to operate incorrectly.

Event on Master Node

Reaction on

Master

Reaction on Stack

Member

Reaction on Stack

Member

With Resiliency Link

Without Resiliency Link

Both stack links removed

No change

Fallback action

1

Re-elect master

2

XEM-STK Removed or Faulty No change

Fallback action

1

Re-elect master

2

Hardware reset (or fault)

Reset / offline

Re-elect master

Re-elect master

2

Run the no stack enable
command

3

No change

Fallback action

1

Not allowed

Displays Error Message

Software application problem
(lock-up or continual crashes)

Reboot as stack
member

Re-elect master

Re-elect master

Software crash or lock-up

Frozen

4

Re-elect master

Re-elect master

Power-down or PSU failure

Powered down

Re-elect master

Re-elect master

Event on Stack Member

Node

Reaction on

Master

Reaction on Stack

Member

Reaction on Stack

Member

Both stack links removed

No change

Fallback action

1

Re-elect master

2

XEM-STK removed or faulty

No change

Fallback action

1

Re-elect master

2

Hardware reset (or fault)

No change

Reset/offline

Reset/offline

Run the no stack enable
command

3

No change

Fallback action

1

Fallback action

1

Software application failover
(lock-up or continual crashes)

No change

Re-boot as slave

Reboot as stack member

software crash or lock-up

No change

Frozen

4

Frozen

4

Power-down / PSU failure

No change

Powered Down

Powered down