Door Ajar Switch Contacts (2) – input from door ajar device.

Door Bell Button Contacts (2) – input from door bell/chime

button.

Shield Contact (1) – used for shielding audio speaker wires.

Speaker Contacts (2) – provides audio connection to door

speaker(s).

Host system RJ11 (J1 Host) modular jack interface —This

jack is provided for connection to your own telephone set, or

business telephone system (PBX or EKTS) (the host system).

Central Office RJ11 (J2) modular jack interface —This jack is
provided for connection to a C.O. telephone line (from

telephone company’s central office).

WARNING:

RISK OF ELECTRICAL SHOCK —

EQUIPMENT MUST BE PROPERLY GROUNDED.

Your AT&T equipment requires a properly grounded

three-prong power receptacle for safe operation. Have

the receptacle checked by a qualified electrician before
connecting this equipment. Do not cut or remove the
third (ground) prong from the power transformer. Do

not use two-prong extension cords or adapters to

defeat the safety features of this equipment. If you

have a two-prong receptacle, it must be replaced with

a three-prong receptacle, installed by a qualified

electrician.