C. specifications, Electrical, Specifications – AT&T Door Phone Controller User Manual

Page 85: Appendix c—specifications electrical, Standards, Electrostatic discharge, Power supply, Page and talk-back, Amplifier, Auxiliary alert

Advertising
background image

Appendix C—Specifications

Electrical

Standards

The Door Answer Controller meets:

U.L. listing requirements

F.C.C. part 15, class B requirements

F.C.C. part 68 requirements

Electrostatic Discharge

Your AT&T Door Phone Controller complies with the ESD
requirements in BELL Pub 48002.

All user accessible connectors and controls have electrostatic

discharge protection.

Power Supply

The AT&T Door Phone Controller is powered by an UL listed

wall mount transformer with a strain relieved cord.

It functions over an input power range of 96 VAC to 129 VAC.

Your AT&T Door Phone Controller has a green LED power

indicator.

A flashing state of 2.5 per second indicates normal power to
the unit and normal microprocessor operation.

A constant ON state indicates a brown-out condition or
microprocessor failure.

A constant OFF state indicates there is no power to the unit.

Page and Talk-Back

Paging output power is 2 watts (continuous) @ 3.35 Vrms (sine

Amplifier

wave). Talk-back input sensitivity:

speaker leads, tip and ring output

Auxiliary Alert

Relay Contact Closures rated at 1

Door Latch Contacts

Relay Contact Closures rated at 2

with 600 microVrms at the

level will be -17 dBm.

amp.

amps.

Specifications C-1

Advertising