Console redirection – Acer Altos G900 User Manual

Page 157

Advertising
background image

141

Console Redirection

This submenu lets you specify the settings for connecting to the RDM
Manager station.

Parameter

Description

Option

Serial Port
Address

Selects the serial port to be used for
connecting to the RDM Manager.

Disabled

Onboard COM A

Onboard COM B

Baud Rate

This parameter lets you set the RDM
connection transfer rate. This
parameter setting depends on your
modem specification; therefore,
before you change the setting of this
parameter, check the documentation
that came with your modem.

9600

19.2 K

38.4 K

57.6 K

115.2 K

Flow Control

Selects whether to enable the flow
control function

None

XON/XOFF

CTS/RTS

CTS/RTS + CD

Console Type

Selects the RDM console type

PC ANSI

VT100+

VT-UTF8

Remote
Console Reset

Selects whether or not to enable the
remote console reset function

Disabled

Enabled