Setting values for the module/debug levels, Draft 1 – Aastra Telecom 9480i Series User Manual

Page 751

Advertising
background image

Troubleshooting

41-001160-03, Rev 00, Releaes 2.4

9-5

Troubleshooting

Setting Values for the Module/Debug Levels

There are 6 debug levels for the modules. Each debug level has a value you can
use to turn individual levels ON and OFF. The following table identifies these
debug levels and their values. The value of “1” (fatal errors) is the default setting
for all modules.

KBD (Keyboard module)

log module kbd

NET (Network module)

log module net

PROVIS (Provisioning module)

log module provis

RTPT (Realtime Transport module)

log module rtpt

SND (Sound module)

log module snd

PROF (Profiler module)

log module prof

XML (Extension Markup Lanaguage)

log module xml

STUN (Simple Traversal of User Datagram
Protocol (UDP) through Network Address
Translation (NAT)

log module stun

Debug Level

Value

Fatal Errors

1 (default)

Errors

2

Warnings

4

Init

8

Functions

16

Info

32

All debug levels
OFF

0

All Debug Levels
ON

65535