Vaddio BRC-H900 Operating User Manual

Page 24

Advertising
background image

Ov
er
v

ie

w

Location and Function of Parts

GB

24

Rear/Bottom

U MODE selector

Select the position corresponding to the VISCA-
controllable camera to be connected.

Note

Set the selector to position 9 when all the connected
cameras are BRC-H900s. For other connections, set
the selector to position 0.

V VISCA RS-232C connector

Connect to the VISCA RS-232C IN connector of
the camera or the BRU-SF10 HD Optical Multiplex
Unit.

W VISCA RS-422 connector

Connect to the VISCA RS-422 connector of the
camera or the BRU-SF10 HD Optical Multiplex
Unit.
An RS-422 connector plug is attached at the
factory.

X TALLY/CONTACT connector

This connector is used for the tally lamp input or the
contact output.
Select the function of the connector using the
TALLY/CONTACT selector.
An RS-422 connector plug is attached at the
factory.

Y TALLY/CONTACT selector

Select the function of the TALLY/CONTACT
connector.
TALLY: The tally lamp of the camera selected with
the connected switcher lights.
CONTACT: The contact output corresponding to
the camera address selected with the Remote
Control Unit is short-circuited against the
connected switcher.
CONTACT (TALLY): The contact output
corresponding to the camera address selected with
the Remote Control Unit is short-circuited against
the connected switcher and the tally lamp of the
camera selected with the connected switcher lights.

Notes

• Change the setting of the selector before you turn

on the power of the Remote Control Unit.
Otherwise, the setting is not effective.

• For details about the TALLY/CONTACT

selector, refer to the Operating Instructions of
RM-BR300.

wh DC IN 12V connector

Connect the supplied AC power adaptor.

wj DIP switches (bottom)

Switch 1 (RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.

Switch 2 (Communication baud rate selector)
Set to ON for 38,400 bps, or OFF for 9,600 bps.

Switch 3 (BRIGHT control function selector)
Set to ON for IRIS and GAIN adjustments, or OFF
for IRIS adjustment only.

Note

Set the DIP switches before you turn on the power
of the Remote Control Unit. Otherwise, the setting
is not effective.

wk ON/OFF switch

Press this switch to turn on/off the Remote Control
Unit.

Switch position

Camera mode

0

Automatically selected (default)

1

BRC-300/300P

2

EVI-D70/D70P

3

EVI-D100/D100P

4

EVI-D30/D30P

5

SNC-RZ30N

6

BRC-H700

7

BRC-Z700

8

BRC-Z330

9

BRC-H900

MODE

VISCA

1

9

1

9

RS-422

ON/OFF

TALLY/CONTACT

RS-232C

CONTACT(TALLY)

!

TALLY

CONTACT

DC IN 12V

ws wd

wf wg wh wj wk

wa

Advertising