• Make sure that the equipment is properly maintained:

• Monitor the pump components and the end temperature of the liquid.
• Maintain proper bearing lubrication.

• Do not modify the equipment without approval from an authorized ITT representative.
• Only use parts that have been provided by an authorized ITT representative.

Equipment for monitoring

For additional safety, use condition-monitoring devices. Condition-monitoring devices include but are not
limited to these devices:

• Pressure gauges
• Flow meters
• Level indicators
• Motor load readings
• Temperature detectors
• Bearing monitors
• Leak detectors
• PumpSmart control system

Product approval standards

Regular standards

All standard products are approved according to CSA standards in Canada and UL standards in USA. The
drive unit degree of protection follows IP68. See the nameplate for maximum submersion, according to
standard IEC 60529.
All electrical ratings and performance of the motors comply with IEC 600341.

Explosion-proofing standards

All explosion-proof products for use in explosive atmospheres are designed in compliance with one or
more of the following approvals:

• EN, ATEX Directive 94/9/EC
• FM According to NEC

• Class 1 Div 1 Groups “C”, and “D”
• Class 2 Div 1 Groups “E”, “F”, and “G”
• Class 3 Div 1 Hazardous Locations

ATEX/IECEx:

• Group: IIC
• Category: Ex ia
• Temperature Class: T4 (for ambients up to 100ºC)
• ATEX Marking: Ex II 1 G

2D Barcode Here

CSA certification

Intrinsically safe for:

• Class I, Div. 1, Groups A, B, C, D
• Class II, Div. 1, Groups E, F, G