General description i-alert™ condition monitor, General description i-alert, Condition monitor – Goulds Pumps NM 3196 i-FRAME - IOM User Manual

Page 18

Advertising
background image

Standard cover

• a fiber-reinforced vinylester cover to fit a clamped outside single seal.

Optional Cover

• the backplate is also available with an internal bypass flush.
• a bolt-on seal chamber is available for conventional back-to-back double seals.

This table describes the main parts of the power end.

Table 4: Power end

Part

Description

Frame adapter

The ductile iron frame adapter has

• a machined rabbet fitted to the seal chamber/ stuffing box cover
• a precision dowel pin fitted to the bearing frame.

Power end

• Flood-oil lubrication is standard.
• No machining is required to convert from oil to grease or oil-mist lubrication.

Regreasable bearings and oil-mist lubrication are optional.

• The oil level is checked through a sight glass.
• The power end is sealed with labyrinth seals.
• The power end is made in the following sizes:
• STi
• MTi

Shaft

The shaft is available with or without a sleeve.

Bearings

The inboard bearing

• carries only radial loads.
• is free to float axially in the frame.
• is a single-row deep-groove ball bearing

The outboard bearing

• is shouldered and locked to the shaft and housing to enable it to carry radial

and thrust loads.

• is a double-row angular-contact bearing.

General description i-ALERT

Condition Monitor

Description

The i-ALERT Condition Monitor is a compact, battery-operated monitoring device that continuously
measures the vibration and temperature of the pump power end. The condition monitor uses blinking red
LEDs to alert the pump operator when the pump exceeds pre-set vibration and temperature limits. This
allows the pump operator to make changes to the process or the pump before a catastrophic failure
occurs. The condition monitor is also equipped with a single green LED to indicate when it is operational
and has sufficient battery life.

Alarm mode

The condition monitor enters alarm mode when either vibration or temperature limits are exceeded over
two consecutive readings within a ten minute period. Alarm mode is indicated with two red flashing LEDs
within two second intervals.

Temperature and vibration limits

Variable

Limit

Temperature

195°F (91°C)

Vibration

100% increase over the baseline level

Battery life

The i-ALERT Condition Monitor battery is not replaceable. You must replace the entire unit once
the battery runs out of power.

Product Description

16

Model NM 3196 i-FRAME Installation, Operation, and Maintenance Manual

Advertising