General description i-alert™ condition monitor, General description i-alert, Condition monitor – Goulds Pumps NM 3196 i-FRAME - IOM User Manual
Page 18
Standard cover
• a fiber-reinforced vinylester cover to fit a clamped outside single seal.
Optional Cover
• the backplate is also available with an internal bypass flush.
• a bolt-on seal chamber is available for conventional back-to-back double seals.
This table describes the main parts of the power end.
Table 4: Power end
Part
Description
Frame adapter
The ductile iron frame adapter has
• a machined rabbet fitted to the seal chamber/ stuffing box cover
• a precision dowel pin fitted to the bearing frame.
Power end
• Flood-oil lubrication is standard.
• No machining is required to convert from oil to grease or oil-mist lubrication.
Regreasable bearings and oil-mist lubrication are optional.
• The oil level is checked through a sight glass.
• The power end is sealed with labyrinth seals.
• The power end is made in the following sizes:
• STi
• MTi
Shaft
The shaft is available with or without a sleeve.
Bearings
The inboard bearing
• carries only radial loads.
• is free to float axially in the frame.
• is a single-row deep-groove ball bearing
The outboard bearing
• is shouldered and locked to the shaft and housing to enable it to carry radial
and thrust loads.
• is a double-row angular-contact bearing.
General description i-ALERT
™
Condition Monitor
Description
The i-ALERT Condition Monitor is a compact, battery-operated monitoring device that continuously
measures the vibration and temperature of the pump power end. The condition monitor uses blinking red
LEDs to alert the pump operator when the pump exceeds pre-set vibration and temperature limits. This
allows the pump operator to make changes to the process or the pump before a catastrophic failure
occurs. The condition monitor is also equipped with a single green LED to indicate when it is operational
and has sufficient battery life.
Alarm mode
The condition monitor enters alarm mode when either vibration or temperature limits are exceeded over
two consecutive readings within a ten minute period. Alarm mode is indicated with two red flashing LEDs
within two second intervals.
Temperature and vibration limits
Variable
Limit
Temperature
195°F (91°C)
Vibration
100% increase over the baseline level
Battery life
The i-ALERT Condition Monitor battery is not replaceable. You must replace the entire unit once
the battery runs out of power.
Product Description
16
Model NM 3196 i-FRAME Installation, Operation, and Maintenance Manual