Goulds Pumps NM 3196 i-FRAME - IOM User Manual
Page 91
If the total indicator reading is greater than 0.001 in. (0.025 mm), then disassemble and determine the
cause.
5. Place the manila gasket (360D) on the frame (228), and hold the gasket in place by inserting the dowel
pins (469B) in their holes.
The gasket is designed to fit only one way.
6. Install the frame adapter.
a) Place the frame adapter (108) onto the frame assembly.
b) Align the bolt holes and dowel locations on the frame adapter with the bolt holes and dowel
locations on the frame.
370B
496B
108
360D
c) Install the dowel pins (469B) and bolts (370B). Tighten the bolts in a criss-cross pattern according
to the specifications in the bolt torque values table.
d) Rotate the shaft 360º to check the adapter fit.
If the total indicator reading is greater than 0.005 in. (0.13 mm), then determine the cause and
correct it before you proceed.
Maintenance
Model NM 3196 i-FRAME Installation, Operation, and Maintenance Manual
89