Commissioning, Startup, Operation, and Shutdown............................................................................................40

Preparation for startup...................................................................................................................................................40
Remove the coupling guard...........................................................................................................................................40
Check the rotation...........................................................................................................................................................43
Impeller-clearance check................................................................................................................................................43

Impeller clearances (NM 3196)..................................................................................................................................43

Impeller-clearance setting..............................................................................................................................................44

Set the impeller clearance - dial indicator method (all except CV 3196) ............................................................44
Set the impeller clearance - feeler gauge method (all except CV 3196) .............................................................45

Couple the pump and driver..........................................................................................................................................45

Install the coupling guard...........................................................................................................................................46
Bearing lubrication.......................................................................................................................................................50

Shaft-sealing options.......................................................................................................................................................52

Mechanical seal options..............................................................................................................................................52
Connection of sealing liquid for mechanical seals..................................................................................................52
Packed stuffing box option.........................................................................................................................................53

Pump priming..................................................................................................................................................................53

Prime the pump with the suction supply below the pump...................................................................................53
Other methods of priming the pump.......................................................................................................................54

Start the pump.................................................................................................................................................................54
Activate the i-ALERT

Condition Monitor..............................................................................................................55

i-ALERT

Condition Monitor routine operation....................................................................................................56

Pump operation precautions.........................................................................................................................................56
Shut down the pump......................................................................................................................................................57
Deactivate the i-ALERT

Condition Monitor..........................................................................................................57

Reset the i-ALERT

Condition Monitor...................................................................................................................57

Make the final alignment of the pump and driver......................................................................................................57

Maintenance......................................................................................................................................................................59

Maintenance schedule.....................................................................................................................................................59
Bearing maintenance.......................................................................................................................................................60

Lubricating-oil requirements......................................................................................................................................60
Regrease the grease-lubricated bearings ..................................................................................................................61
Lubricate the bearings after a shutdown period......................................................................................................62

Shaft seal maintenance...................................................................................................................................................62

Mechanical-seal maintenance.....................................................................................................................................62

Disassembly......................................................................................................................................................................63

Disassembly precautions.............................................................................................................................................63
Tools required...............................................................................................................................................................63
Drain the pump............................................................................................................................................................64
Remove the coupling...................................................................................................................................................64
Remove the back pull-out assembly..........................................................................................................................64
Remove the coupling hub...........................................................................................................................................67
Impeller removal..........................................................................................................................................................67
Seal-chamber cover removal.......................................................................................................................................68
Remove the seal-chamber cover and backplate (NM 3196, 3198).......................................................................68
Remove the frame adapter (MTi) .............................................................................................................................69
Remove the inboard labyrinth oil seal.......................................................................................................................70
Power-end disassembly...............................................................................................................................................70
Disassemble the bearing frame..................................................................................................................................73
Guidelines for i-ALERT

Condition Monitor disposal.......................................................................................74

Disassemble the C-face adapter.................................................................................................................................74

Pre-assembly inspections...............................................................................................................................................75

Replacement guidelines...............................................................................................................................................75
Shaft and sleeve replacement guidelines...................................................................................................................76
Bearing-frame inspection............................................................................................................................................77