Final alignment (hot alignment) checks

When

Why

After the first run

This ensures correct alignment when both the pump and the driver

are at operating temperature.

Periodically

This follows the plant operating procedures.

Permitted indicator values for alignment checks

NOTICE: The specified permitted reading values are valid only at operating temperature. For cold
settings, other values are permitted. You must use the correct tolerances. Failure to do so can result in
misalignment and reduced pump reliability.

When dial indicators are used to check the final alignment, the pump and drive unit are correctly aligned
when these conditions are true:

• The total indicator runout is a maximum of 0.002 in. (0.05 mm) at operating temperature.
• The tolerance of the indicator is 0.0005 in./in. (0.0127 mm/mm) of indicator separation at operating

temperature.

Cold settings for parallel vertical alignment

Introduction

This section shows the recommended preliminary (cold) settings for electric motor-driven pumps based on
different temperatures of pumped fluid. Consult driver manufacturers for recommended cold settings for
other types of drivers such as steam turbines and engines.

Recommended settings for model NM 3196

Pump temperature

Recommended setting

50°F (10°C)

0.002 in. (0.05 mm), low

150°F (65°C)

0.001 in. (0.03 mm), high

250°F (120°C)

0.005 in. (0.12 mm), high

350°F (175°C)

Not applicable

450°F (218°C)

Not applicable

550°F (228°C)

Not applicable

650°F (343°C)

Not applicable

700°F (371°C)

Not applicable

Alignment measurement guidelines

Guideline

Explanation

Rotate the pump coupling half and the driver coupling half

together so that the indicator rods have contact with the same

points on the driver coupling half.

This prevents incorrect measurement.

Move or shim only the driver in order to make adjustments.

This prevents strain on the piping

installations.

Make sure that the hold-down bolts for the driver feet are

tight when you take indicator measurements.

This keeps the driver stationary since

movement causes incorrect

measurement.