When the reading
value is...

Then...

Negative

The pump coupling half (X) is lower than the driver coupling half (Y). Remove

shims of a thickness equal to half of the indicator reading value under each

driver foot.

Positive

The pump coupling half (X) is higher than the driver coupling half (Y). Add

shims of a thickness equal to half of the indicator reading value to each driver

foot.

NOTICE:
You must use an equal amount of shims with each driver foot to prevent misalignment. Failure to do
so can result in equipment damage or decreased performance.

Y X

Shims

Figure 13: Side view of an incorrect vertical alignment

4. Repeat the previous steps until the permitted reading value is achieved.

Perform parallel alignment for a horizontal correction

A unit is in parallel alignment when the parallel indicator (P) does not vary by more than 0.002 in.
(0.05 mm) as measured at four points 90° apart at the operating temperature.
1. Set the parallel alignment indicator (P) to zero on the left side of the driver coupling half (Y), 90°

from the top-center position (9 o’clock).

2. Rotate the indicator through the top-center position to the right side, 180° from the start position

(3 o’clock).

3. Record the indicator reading.

When the reading value
is...

Then...

Negative

The driver coupling half (Y) is to the left of the pump coupling half

(X).

Positive

The driver coupling half (Y) is to the right of the pump coupling half

(X).

4. Slide the driver carefully in the appropriate direction.

NOTICE: Make sure to slide the driver evenly. Failure to do so can negatively affect horizontal
angular correction.

Y X

Figure 14: Top view of an incorrect horizontal alignment

5. Repeat the previous steps until the permitted reading value is achieved.

Installation

32

Model NM 3196 i-FRAME Installation, Operation, and Maintenance Manual