Nameplate information – Goulds Pumps NM 3196 i-FRAME - IOM User Manual
Page 19
The battery life is not covered as part of the standard five-year pump warranty.
This table shows the average condition monitor battery life under normal and alarm-mode operating
conditions.
Condition monitor operational state
Battery life
Normal operating and environmental conditions
Three to five years
Alarm mode
One year
Nameplate information
Important information for ordering
Every pump has nameplates that provide information about the pump. The nameplates are located on the
casing and the bearing frame.
When you order spare parts, identify this pump information:
• Model
• Size
• Serial number
• Item numbers of the required parts
Refer to the nameplate on the pump casing for most of the information. See Parts List for item numbers.
Nameplate types
Nameplate
Description
Pump casing
Provides information about the hydraulic characteristics of the pump.
The formula for the pump size is: Discharge x Suction - Nominal Maximum Impeller
Diameter in inches.
(Example: 2x3-8)
Bearing frame
Provides information about the lubrication system used.
ATEX
If applicable, your pump unit might have an ATEX nameplate affixed to the pump, the
baseplate, or the discharge head. The nameplate provides information about the ATEX
specifications of this pump.
IECEx
If applicable, your pump unit might have the following IECEx nameplate affixed to the
pump and/or baseplate. The nameplate provides information about the IECEx
specifications of this pump.
Nameplate on the pump casing using English units
Table 5: Explanation of nameplate on the pump casing
Nameplate field Explanation
IMPLR. DIA.
Impeller diameter, in inches
MAX. DIA.
Maximum impeller diameter, in inches
GPM
Rated pump flow, in gallons per minute
FT HD
Rated pump head, in feet
RPM
Rated pump speed, revolutions per minute
Product Description
Model NM 3196 i-FRAME Installation, Operation, and Maintenance Manual
17