Goulds Pumps NM 3196 i-FRAME - IOM User Manual

Page 90

Advertising
background image

If the total indicator reading is greater than the values in this table, then disassemble the shaft and
determine the cause.
Use this table as a reference for shaft-end play values.

Table 14: Shaft-end play

Frame

Double row bearing

Duplex bearing

STi inches (millimeters)

0.0011 (0.028)
0.0019 (0.048)

0.0007 (0.018)
0.0010 (0.025)

MTi inches (millimeters)

0.0013 (0.033)
0.0021 (0.053)

0.0009 (0.023)
0.0012 (0.030)

SCALE

0.160

3. Check the shaft-sleeve (126) runout.

a) Install the shaft sleeve.
b) Thread the impeller on the shaft until hand tight.
c) Rotate the shaft 360º.
d) If the total indicator reading is greater than 0.002 in. (0.051 mm), then disassemble the shaft sleeve

and determine the cause.

e) Remove the impeller and shaft sleeve.

SCALE

0.150

4. Check the frame-face runout by rotating the shaft so that the indicator measures the fit for 360º.

Maintenance

88

Model NM 3196 i-FRAME Installation, Operation, and Maintenance Manual

Advertising