4. Commissioning

4−15

Festo P.BE−SPC200−COM−PDP−E N en 0901c

SYNC

The outputs of the master are mapped on internal inputs of
the field bus module. With this control command the interĆ
nal inputs can be frozen." The SPC200 then no longer reĆ
acts to modifications to the output image in the master. The
following SYNC command causes the output image of the
master to be updated.

Return to normal operation UNSYNC command.

4.4.2 Configuration of the I/O address range

The size of the I/O address range to be configured depends
on the operating mode of the SPC200 used and on the addiĆ
tional functions used (parameter channel and transmission of
the actual positions).

Function

Address range equired

Consistency of

I/O signals
(I10 0 I13 15

Start/Stop mode

1)

(I10.0...I13.15,
Q10.0...Q13.15)

2, 4, 6 or 8 I−bytes
2, 4, 6 or 8 O−bytes

1 I−byte or complete length
1 O−byte or complete length

Record Select mode

2 I−bytes
4 O−bytes

Complete length
Complete length

Parameter channel

2)

(optional)

4 I−words
4 O−words

Complete length

Actual positions

2)

(optional)

2 I−words per axis

Complete length

Setpoint positions

3)

(optional)

2 O−words per axis

Complete length

1) Freely programmable I/Os are only available in the operating mode Start/Stop.
2) For this function you require a field bus module with firmware version as from V 2.0, an SPC200

with operating system version as from V 4.6 and WinPISA as from version 4.3.

3) For this function you require a fieldbus module with firmware version as from V 2.1, an SPC200

with operating system version as from V 4.82 and WinPISA as from version 4.41.