Festo Контроллер крайних положений SPC11 User Manual

Page 21

Advertising
background image

1. Installation instructions for the DNCM-...-POT

1-9

Festo P.BE-SPC11-DNCM-EN en 0204NH

Standard cylinder with built-on measuring system
type DNCM-...-POT ( 6 )

The standard cylinder and measuring system are fitted sym-
metrically at the factory. The parameters listed in chapter 2
are matched to this symmetrical fitting.

Caution
Even slight deviations from the necessary symmetry be-
tween the measuring system and the standard cylinder can
lead to bad positioning during operation. In extreme cases
the measuring system can be damaged. Do not loosen the
mechanical connections between the standard cylinder
housing and the measuring system housing. When fitting
the coupling plate observe the instructions in the operat-
ing instructions for the DNCM-...-POT.

Fig. 1/4: Do not loosen the mechanical connection

Use only:

– Permitted combinations of drives, valves and mass loads

see “Parameters for the DNCM-...” in chapter 2.

Fit the drive horizontally or vertically.

Parameters for the DNCM-...-POT in vertical operation are
available on request.

Advertising