2. Parameters of the SPC11 for the DGP(I)(L)-...

2-4

Festo P.BE-SPC11-DGP-EN en 0012NH

Specifications for setting the parameters

In order to set the parameters, you will require the following
specifications:

Cylinder stroke length (see type plate for drive used).

Valve type (see type plate for proportional directional
control valve used).

Maximum mass load with which the drive is loaded.

Mass load

If you wish to position with different masses:

Positioning with a mass up to 30 % less does not usually
present any problems. Further reduction of the mass can
lead to worse positioning behaviour and make optimiz-
ation necessary (see System manual).

If necessary, place a basic load on the drive, in order to be
able to set a higher mass. Positioning can then be carried
out with masses of larger sizes.

Always set the amplification and cushioning stages for the
maximum mass load used.