2. Parameters of the SPC11 for the DGP(I)(L)-...

2-30

Festo P.BE-SPC11-DGP-EN en 0012NH

DGP(I)(L)-25-750 to ...-25-1250 in vertical operation

DGP(I)(L)-25-750

DGP(I)(L)-25-1000

DGP(I)(L)-25-1250

MPYE-5-1/8-HF-010B

MPYE-5-1/4-010B

MPYE-5-1/4-010B

Ma

ss

[k

g

]

Amplif

ic

a

tion

st

a

ge

Cushion

in

g

st

a

g

e

Sys

te

m

p

a

ra

m

e

te

r

T

ime

upwa

rds

[s

]

T

ime

down

w

a

rds

[s

]

Amplif

ic

a

tion

st

a

ge

Cushion

in

g

st

a

g

e

Sys

te

m

p

a

ra

m

e

te

r

T

ime

upwa

rds

[s

]

T

ime

down

w

a

rds

[s

]

Amplif

ic

a

tion

st

a

ge

Cushion

in

g

st

a

g

e

Sys

te

m

p

a

ra

m

e

te

r

T

ime

upwa

rds

[s

]

T

ime

down

w

a

rds

[s

]

2

18

20

13

0.66

0.59

19

22

22

0.78

0.72

20

23

22

0.95

0.83

4

20

23

13

0.74

0.63

21

25

22

0.86

0.74

22

26

22

1.01

0.86

6

21

26

13

0.82

0.66

22

27

22

0.98

0.75

23

29

22

1.15

0.89

8

23

26

13

0.85

0.63

23

28

22

1.00

0.75

24

30

22

1.27

0.84

10

23

30

13

0.99

0.70

24

31

22

1.14

0.77

25

31

22

1.38

0.85