2 dgp(i)(l)-32-... in vertical operation – Festo Контроллер крайних положений SPC11 User Manual

Page 64

Advertising
background image

2. Parameters of the SPC11 for the DGP(I)(L)-...

2-32

Festo P.BE-SPC11-DGP-EN en 0012NH

2.4.2 DGP(I)(L)-32-... in vertical operation

DGP(I)(L)-32-225 to ...-32-360 in vertical operation

DGP(I)(L)-32-225

DGP(I)(L)-32-300

DGP(I)(L)-32-360

MPYE-5-1/8-LF-010B

MPYE-5-1/8-LF-010B

MPYE-5-1/8-LF-010B

Ma

ss

[k

g

]

Amplif

ic

a

tion

st

a

ge

Cushion

in

g

st

a

ge

S

ys

tem

p

ar

am

eter

T

ime

upwa

rds

[s

]

T

ime

down

w

a

rds

[s

]

Amplif

ic

a

tion

st

a

ge

Cushion

in

g

st

a

ge

S

ys

tem

p

ar

am

eter

T

ime

upwa

rds

[s

]

T

ime

down

w

a

rds

[s

]

Amplif

ic

a

tion

st

a

ge

Cushion

in

g

st

a

ge

S

ys

tem

p

ar

am

eter

T

ime

upwa

rds

[s

]

T

ime

down

w

a

rds

[s

]

3

10

14

13

0.53

0.53

13

15

14

0.60

0.59

15

15

25

0.64

0.60

6

12

17

13

0.58

0.53

15

19

14

0.66

0.59

17

19

25

0.71

0.62

9

14

20

13

0.65

0.54

17

20

14

0.69

0.58

19

22

25

0.75

0.73

12

15

22

13

0.70

0.60

18

23

14

0.73

0.73

20

23

25

0.82

0.77

15

16

23

13

0.79

0.62

19

24

14

0.76

0.72

21

25

25

0.88

0.87

Advertising