2. Installation

2−10

Festo P.BE−CPX−CEC−EN en 1004a

2.5

Ethernet interface

The Ethernet interface permits connection of a programming
device, PC or type FED operator unit to the CoDeSys
controller.

The Ethernet interface is designed as an RJ45 socket.

Socket

Pin

Signal

Explanation

1

2

3

4

5

6

7

8

1
2
3
4
5
6
7
8
Housing

TD+
TDć
RD+
n.c.
n.c.
RDć
n.c.
n.c.
Shield

Transmitted data+
Transmitted datać
Received data+
not connected
not connected
Received datać
not connected
not connected
Screening

Tab. 2/4:

Pin assignment of the Ethernet interface

If the Ethernet interface is not used, close it with the AK−RJ45
cover. In this way you will comply with protection class
IP65/IP67.

2.5.1

Ethernet cable

Use as connecting cable:

Cable specification

Screened flexible Ethernet round cable of category 5
Max. outer diameter:

5.4 mm

Core diameter:

0.89 ... 1.0 mm AWG24−26

Ready made:

Crimping pliers on RJ45