Connecting the VP-8x4 8x4 VGA / UXGA Matrix Switcher

11

6.2 Controlling via RS-232 (for example, using a PC)

To connect a PC to the

VP-8x4 unit, using the null-modem adapter provided

with the machine (recommended):

Connect the null-modem adapter to the RS-232 9-pin D-sub port on the

rear panel of the Master

VP-8x4. Connect the null-modem adapter to the

RS-232 9-pin D-sub port on your PC with a 9-wire flat cable

To connect a PC to the

VP-8x4 unit, without using a null-modem adapter:

Connect the RS-232 9-pin D-sub port on your PC to the RS-232 9-pin

D-sub rear panel port on the Master

VP-8x4 unit, as Figure 4 illustrates

9-pin D-sub

(From PC)

9-pin D-sub

(Male)

If a shielded cable is used, connect the shield to PIN 5

PIN 4 is connected to PIN 6

PINs 8, 7, 1 are connected together

PIN 5 Connected to PIN 5 (Ground)

PIN 3 Connected to PIN 2

PIN 2 Connected to PIN 3

Figure 4: Connecting a PC without using a Null-modem Adapter

6.3 Controlling via RS-485

You can control a

VP-8x4 unit via an RS-485 controller, for example, a PC

(equipped with an RS-485 interface) or a Master Programmable Remote

Control system such as the Kramer

RC-3000.

To connect an

RC-3000 to a VP-8x4 unit (see Figure 5):

1. Connect the RS-485 terminal block port on the

RC-3000 to the RS-485

port on the

VP-8x4 unit, as follows:

Connect the “ A” (+) PIN on the RS-485 rear panel port of the

RC-3000 to the “ A” (+) PIN on the RS-485 rear panel port of the

VP-8x4 unit

Connect the “ B” (-) PIN on the RS-485 rear panel port of the RC-3000

to the “ B” (-) PIN on the RS-485 rear panel port of the

VP-8x4 unit

If shielded twisted pair cable is used, the shield may be connected to the

“ G” (Ground) PIN on one of the units (for example, on the RC-3000)

2. Set the

VP-8x4 unit as Machine # 1, according to Table 6 (that is, DIP 1,

DIP 2, DIP 3, and DIP 4 OFF), and set the other dipswitches on the

VP-8x4 unit, as follows:

Set DIP 5, DIP 6, and DIP 7 OFF

Set DIP 8 ON (for RS-485 Line Termination with 120 )