Table 5: delay dip-switch settings, 2 setting the machine # dip-switches, Table 6: machine # dip-switch settings – Kramer Electronics VP-8x4 User Manual

Page 16

Advertising
background image

Connecting the VP-8x4 8x4 VGA / UXGA Matrix Switcher

13

6.5.1 Setting the Delay

You can achieve clean transitions when switching between non-genlocked

sources by setting the delay time—ranging from 0 sec to 3.5 sec

1

—via the

DELAY DIP-switches, as Table 5 defines. The

VP-8x4 unit is shipped (its

factory default state) with no delay, that is, the DELAY DIP-switches are set up

for a 0 sec delay. The delay time is the period where the output will be forced

to black when switching between inputs.

Table 5: DELAY DIP-switch Settings

sec

DIP 1

DIP 2

DIP 3

0

OFF

OFF

OFF

0.5

OFF

OFF

ON

1.0

OFF

ON

OFF

1.5

OFF

ON

ON

2.0

ON

OFF

OFF

2.5

ON

OFF

ON

3.0

ON

ON

OFF

3.5

ON

ON

ON

6.5.2 Setting the Machine # DIP-switches

The Machine # determines the address of a

VP-8x4 unit, specifying which

VP-8x4 unit is being controlled when several VP-8x4 units are connected to a

PC or serial controller. Set the Machine # on a

VP-8x4 unit via MACH# DIPs

4, 5, 6 and 7, according to Table 6.
When using a standalone

VP-8x4 unit, set the Machine # to 1. When

connecting more than one

VP-8x4 unit, set the first machine (the Master) that

is closest to the PC, as Machine # 1 (DIP-switches are set to OFF).

Table 6: Machine # DIP-switch Settings

Mach. #

DIP 4

DIP 5

DIP 6

DIP 7

Mach. #

DIP 4

DIP 5

DIP 6

DIP 7

1

OFF

OFF

OFF

OFF

9

ON

OFF

OFF

OFF

2

OFF

OFF

OFF

ON

10

ON

OFF

OFF

ON

3

OFF

OFF

ON

OFF

11

ON

OFF

ON

OFF

4

OFF

OFF

ON

ON

12

ON

OFF

ON

ON

5

OFF

ON

OFF

OFF

13

ON

ON

OFF

OFF

6

OFF

ON

OFF

ON

14

ON

ON

OFF

ON

7

OFF

ON

ON

OFF

15

ON

ON

ON

OFF

8

OFF

ON

ON

ON

16

ON

ON

ON

ON


1 In increments of 0.5sec