Kramer Electronics VP-8x4 User Manual

Page 17

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Connecting the VP-8x4 8x4 VGA / UXGA Matrix Switcher

14

6.6 Cascading Machines

You can cascade up to 16

VP-8x4 units with control from a PC or serial

controller (see Figure 7).
To cascade up to 16 individual

VP-8x4 units via RS-485, do the following:

1. Connect the VGA/UXGA sources and acceptors, as section 6.1 describes.
2. Connect the RS-232 port

1

on the first

VP-8x4 unit to the PC using the

null-modem adapter provided with the machine (recommended), as section

6.2 describes.

3. Connect the RS-485 terminal block port on the first unit to the RS-485 port

on the second

VP-8x4 unit and so on, connecting all the RS-485 ports.

4. Set the dipswitches, as section 6.4 describes:

Set the first

VP-8x4 unit as Machine # 1 and the following 15 VP-8x4

units as Machine # 2 to Machine # 16, according to Table 6

Set DIP 8 ON on the first and last

VP-8x4 units (terminating the

RS-485 line at 120 ). Set DIP 8 OFF on the other

VP-8x4 units

Set DIP 5, DIP 6 and DIP 7 OFF on all

VP-8x4 units

1 Alternatively, the RS-485 port could be used for PC control (instead of RS-232)

Advertising