Connecting the VP-8x4 8x4 VGA / UXGA Matrix Switcher
12
Figure 5: Controlling via RS-485 (for example, using an RC-3000)
6.4 Control Configuration via the Ethernet Port
To connect and configure the Ethernet port of the
VP-8x4, refer to the
ETHERNET Configuration (Lantronix) GUIDE on our Web site:
http://www.kramerelectronics.com.
6.5 Setting the DIP-switches
By default, all dipswitches are set to OFF. Figure 6 illustrates the
VP-8x4
DIP-switches:
Figure 6: VP-8x4 DIP-switches
Table 4: DIP-switch Settings
DIPS
Function
Description
1, 2, 3
DELAY
Determines switching delay time
4, 5, 6, 7
Machine #
Determines the number of the machine in the sequence
8
RS-485 TERM
ON for RS-485 line termination with 120 ;
OFF for no RS-485 line termination