Kramer protocol 2000, Table 10: protocol definitions – Kramer Electronics VP-8x4 User Manual

Page 30

Advertising
background image

Kramer Protocol 2000

27

11 Kramer Protocol 2000

1

The

VP-8x4 is compatible with Kramer’s Protocol 2000

2

, version 0.50. This

RS-232/RS-485 communication protocol uses four bytes of information as

defined below. For RS-232, a null-modem connection between the machine

and controller is used. The default data rate is 9600 baud, with no parity, 8

data bits, and 1 stop bit.

Table 10: Protocol Definitions

MSB

LSB

DESTI-

NATION

INSTRUCTION

0

D

N5

N4

N3

N2

N1

N0

7

6

5

4

3

2

1

0

1st byte

INPUT

1

I6

I5

I4

I3

I2

I1

I0

7

6

5

4

3

2

1

0

2nd byte

OUTPUT

1

O6

O5

O4

O3

O2

O1

O0

7

6

5

4

3

2

1

0

3rd byte

MACHINE NUMBER

1

OVR

X

M4

M3

M2

M1

M0

7

6

5

4

3

2

1

0

4th byte

1

st

BYTE:

Bit 7 – Defined as 0.

D – “ DESTINATION” :

0 - for sending information to the switchers (from the PC);

1 - for sending to the PC (from the switcher).

N5…N0 – “ INSTRUCTION”

The function that is to be performed by the switcher(s) is defined by the INSTRUCTION (6 bits). Similarly, if a function is

performed via the machine’s keyboard, then these bits are set with the INSTRUCTION NO., which was performed. The

instruction codes are defined according to the table below (INSTRUCTION NO. is the value to be set for N5…N0).

2

nd

BYTE:

Bit 7 – Defined as 1.

I6…I0 – “ INPUT” .

When switching (ie. instruction codes 1 and 2), the INPUT (7 bits) is set as the input number which is to be switched.

Similarly, if switching is done via the machine’s front-panel, then these bits are set with the INPUT NUMBER which was

switched. For other operations, these bits are defined according to the table.

3

rd

BYTE:

Bit 7 – Defined as 1.

O6…O0 – “ OUTPUT” .

When switching (ie. instruction codes 1 and 2), the OUTPUT (7 bits) is set as the output number which is to be switched.

Similarly, if switching is done via the machine’s front-panel, then these bits are set with the OUTPUT NUMBER which was

switched. For other operations, these bits are defined according to the table.

1 You can download our user-friendly “ Software for Calculating Hex Codes for Protocol 2000” from the technical support
section on our Web site at: http://www.kramerelectronics.com
2 The instruction codes in Table 11 are a sub-set of the Protocol 2000. You can find the full protocol on our Web site at
http://www.kramerelectronics.com