Operating Instructions Temperature Indicating Controller CS4H / CS4L

V1.1

05/2006

- 4 -

List of contents

1. Model informations

1.1 Model name ····················································································································· 6
1.2 Rated input ······················································································································· 7

2. Name and functions of the sections

········································································ 8

3. Mounting to control panel

3.1 Site selection ·················································································································· 10
3.2 External dimension ········································································································· 10
3.3 Panel cutout ····················································································································11
3.4 CT (current transformer) external dimension ···································································11
3.5 Mounting ························································································································ 12

4. Wiring connection

4.1 Terminal arrangement ···································································································· 13
4.2 Wiring connection example ···························································································· 14

5. Setup

5.1 Setup flow chart ············································································································· 17
5.2 Main setting mode

SV1 ································································································································· 19
SV2 ································································································································· 19

5.3 Sub setting mode

AT setting/Auto-reset setting ··························································································· 19
OUT1 proportional band setting ······················································································ 19
OUT2 proportional band setting ······················································································ 19
Integral time setting ········································································································· 20
Derivative time setting ····································································································· 20
ARW (Anti-reset windup) setting ····················································································· 20
OUT1 proportional cycle setting ······················································································ 20
OUT2 proportional cycle setting ······················································································ 20
A1 setting ························································································································ 20
A2 setting ························································································································ 20
HB (Heater burnout alarm) setting ··················································································· 21
LA (Loop break alarm) action time setting ······································································· 21
LA (Loop break alarm) action span setting ······································································ 21

5.4 Auxiliary function setting mode 1

Setting value lock selection ····························································································· 22
SV high limit setting ········································································································· 22
SV low limit setting ·········································································································· 22
Sensor correction setting ································································································· 22
Communication protocol selection ··················································································· 22
Instrument number setting ······························································································· 22
Data transfer rate selection ····························································································· 23
Parity selection ················································································································ 23
Stop bit selection ············································································································· 23

5.5 Auxiliary function setting mode 2

Sensor selection ·············································································································· 24
Scaling high limit setting ·································································································· 24
Scaling low limit setting ··································································································· 24
Decimal point place selection ·························································································· 25
PV filter time constant setting ·························································································· 25
OUT1 high limit setting ···································································································· 25
OUT1 low limit setting ····································································································· 25
OUT1 ON/OFF action hysteresis setting ········································································· 25
OUT2 action mode selection ··························································································· 25
OUT2 high limit setting ···································································································· 25
OUT2 low limit setting ····································································································· 25
Overlap band/Dead band setting ····················································································· 26
OUT2 ON/OFF action hysteresis setting ········································································· 26
A1 action selection ·········································································································· 26