3 Specifications

10

WIKA operating instructions digital indicator DI35-M

{Switching outputs}

number and type

2 or 4 change-over contacts (relays), fully
programmable

Load

AC 230 V, 5 A (ohmic load) or
DC 30 V, 2 A (ohmic load)

Switching cycles

0.5 * 10

5

at max contact rating

5 * 10

6

mechanically

Separation as per DIN EN 50178
Characteristic data as per DIN EN 60255

{Serial Interface}

RS 232, selectable with or without galvanic
isolation or
RS 485 (only for point-to-point connection),
selectable with or without galvanic isolation

Protocol

manufacturer-specific ASCII

communication

9600 Baud, no parity, 8 data bits, 1 stop bit

Lead length

RS 232: max. 3 m
RS 485: max. 1000 m

Case

Material

PC polycarbonate, ABS Blend, UL 94V-0,
black

Ingress protection

Front: IP 54, {IP 65};
Back: IP 00 (per IEC 60529 / EN 60529)

Weight

Approx. 450 g

Dimensions

96 x 48 x 148 mm (w x h x d) including plug-in
terminals

Mounting

snap-in screw element for wall thickness up to
50 mm

Permissible ambient conditions

Operating temperature

0…60 °C

Storage temperature

-20…80 °C

Humidity

0…75 % relative humidity, non-condensing

CE conformity

EMC directive

2004/108/EC, EN 61326 emission (group 1,
class B) and interference immunity (industrial
application)

Low voltage directive

2006/95/EG, EN 61010-1