Factory settings, Specifying the settings, P. 2-18 – Konica Minolta bizhub C200 User Manual

Page 67

Advertising
background image

C200

2-18

Specifying machine functions (software switch settings)

2

2.4.16

Specifying settings concerning the encryption method for SSL/TLS and the SNMP
protocol (mode 389)

Specify settings concerning the encryption method for SSL/TLS and the SNMP protocol.

Factory settings

Specifying the settings

During the production of this unit, the settings in the shaded cells were selected.

Bits

7654 3210

Settings

0000 1100 (HEX: 0C)

Bits

Description

Settings

Details

7-6

00

*Do not change the settings
for these bits.

5-4

Specify the encryption method for SSL/TLS.

00

3DES_168bits/RC4_128bits
/DES_56bits or RC4_40bits

01

RC4_128bits/DES_56bits or
RC4_40bits

10

DES_56bits or RC4_40bits

11

*Do not specify these set-
tings.

3

Specify whether or not to enable write permissions.

0

Disable

1

Enable

2

Specify whether or not to enable discover user permissions.

0

Disable

1

Enable

1-0

-

00

* Do not change the settings
for these bits.

Advertising