5-4

Getting Started

R5976336 BARCOSLM R6 Executive 06092001

Select with é or ê

then <ENTER>

<EXIT> to return.

ADJUSTMENT MODE

Select a path from below :

RANDOM ACCESS

INSTALLATION

SERVICE

Select with é or ê

then <ENTER>

<EXIT> to return.

SERVICE

IDENTIFICATION

CHANGE PASSWORD

CHANGE LANGUAGE

CHANGE PROJ. ADDRESS

SERIAL COMMUNICATION

LAMP

MORE..

Select with é or ê

then <ENTER>

<EXIT> to return.

CHANGE LANGUAGE

English

menu 1

menu 2

menu 3

Lamp Light Output Indication

When starting up and the center lumens measurement is lower than 50 % of its initial value, the lamp light output warning will be displayed

for 1 minute. Press ENTER to continue. The message will not be repeated during operation.

<ENTER> to confirm

WARNING

Lamp run time is 1400 hours.

The light output of the lamp is less

than 50% of its initial value.

It is advisable to replace the lamp

before damage occurs.

When the 'Constant Light Ouput' (CLO) options is installed, the light output message will appear on the screen when the light output

is reduced with 33% from its initial value.

This message will be repeated every hour.

Switching to Stand-by.

When the projector is running and you want to go to stand-by, press the stand-by key.

Switching Off

To switch off:

- First press STANDBY key and let the projector cool down until the fans stopblowing, or at least 15 min.

- Switch off the projector with the power switch.

Temperature error DMD

When the temperature of one of the DMD is too low or too high the projector will be switched automatically to standby. Before switching

to standby, the following message appears for 3 seconds on the screen : 'DMD out of operating temperature range. Automatic

shutdown is activated.'.

A '-t' appears on the LED display to indicate the user that the projector is switched to standby due to DMD temperature problems.

ERROR

DMD out of operating temperature

range.

Automatic shutdown is activated

Quick Set Up Adjustments

Quick Language Change

Only if different on screen languages are available, follow the next procedure to change the on screen language.

1 Press ENTER to start up the adjustment mode.

2 Press the cursor key é or ê to highlight 'Service' (menu 1). When password protected, your password will be asked.

(more explanation about access by password can be found in Chapter 'Start up the Adjustment mode'.

3 Press ENTER to display the Service mode menu.

3 Push the cursor key é or ê to highlight 'Change Language' (menu 2). If not visible in the menu, highlight first 'More' and press

ENTER to display a second service menu. Select then 'Change Language'.

4 Press ENTER to display the language selection menu.

5 Push the cursor key é or ê to highlight the desired language (menu 3).

For the moment, only English is available.

Advertising