Work steps:

1. First of all, carefully clean the rescue equipment.

2. Remove the fi xing screws "A" and

remove the protective cover "B" and the
cover caps "C".

E

F

3. Move the blade arms on the unit

until the pin "E" and the retaining
rings "F" can be accessed through
the hole "D".

Now switch off the device and
remove the battery or unplug the
power supply from the device.