6 operating and storage temperature ranges, 7 oscillation / vibration – Lukas SC 350 E User Manual

Page 42

Advertising
background image

42

11.6 Operating and storage temperature ranges

Operating temperature

[°C] /

[°F]

-20 … +55

-4 …

+131

Ambient temperature
(device in operation)

[°C] /

[°F]

-25 … +45

-13 …

+113

Storage temperature
(device not in operation)

[°C] /

[°F]

-30 … +60

-22 …

+140

11.7 Oscillation / vibration

The total oscillation value / vibration value to which the upper limbs are exposed, is usually
below 2.5 m/s².
Higher values may be measured for short periods as a result of interaction with the materials
to be processed.

(The oscillations / vibrations were determined in accordance with DIN EN ISO 20643.)

11.5.2 R411E:

Battery type used for device

Lithium / ion

No-load operation

(measuring distance: 1m)

[dB(A)]

78

full load operation

(measuring distance: 1m)

[dB(A)]

79

No-load operation

(measuring distance: 5m)

[dB(A)]

71

full load operation

(measuring distance: 5m)

[dB(A)]

72

11.8 Tightening torques for pivot bolts (cutters and combi tools only)

type

S 311 E

S 700 E

SC 250 E

SC 350 E

pivot bolt

M 24 x 1,5

M32 x 1,5

M 24 x 2

M 24 x 1,5

wrench size

[mm]

36

46

36

36

[in.]

1.42

1.81

1.42

1.42

torque

[Nm]

120 +10

140 + 10

110 +10

120 +10

[lbf.in.] 1,062 + 89

1,239 + 89

890 + 89

1,062 + 89

Advertising
This manual is related to the following products: