10

NOTE:
Always register your hydraulic unit on the LUKAS Hydraulik GmbH internet site.
Only then are you entitled to the extended guarantee.

Before you use couplings from a different company, you must contact LUKAS or
an authorised dealer.

The P600OE is fi tted with a single fl ow pump with two pressure stages, a low pressure stage
and a high pressure stage.

Low pressure stage (ND)

=

up to 14 MPa*

High pressure stage (HD)

=

up to 70 MPa*

The changeover from low pressure to high pressure is carried out automatically in the pump.
The maximum pressure is limited by a pressure limiting valve.

*) 1 MPa = 10 bar)

Connection with the rescue equipment is via extension hose pairs or a hose reel. They are
supplied in various lengths and kink-protection colours. The individual hoses in a pair of
hoses can be distinguished by their different colours.
(For specifi c details, please consult the LUKAS range of accessories or contact your
LUKAS dealer.

Lukas recommends that you do not use more than 10 m of total hose

length between the hydraulic pump and the rescue unit.

You can order replacement parts and accessories for the P600OE from your authorised
LUKAS dealer!

In addition, the P600OE is fi tted with LED lighting as standard in order to make working
under reduced visibility conditions easier.
The light-emitting diodes attached on the connection side light up the coupling area. The
main switch has also been provided with a light, so that you can see at a glance whether
the device is switched on.
The hydraulic tank is also lit. This allows you to see the fi ll level at any time if the lighting
conditions are poor.