12.4 Operating and storage temperature ranges

Operating temperature

[°C] /

[°F]

-20 …

+55

-4 …

+131

Ambient temperature
(device in operation)

[°C] /

[°F]

-25 …

+45

-13 …

+113

Storage temperature
(device not in operation)

[°C] /

[°F]

-30 …

+60

-22 …

+140

12.5 Oscillation / vibration

The total oscillation value / vibration value to which the upper limbs are exposed, is below
2.5 m/s².

12.2 Noise emissions (based on the EN ISO 3744 standard)

Used power source

Lithium-ion battery

Power supply

Idling (measured at
a distance of 1 m)

[dB(A)]

54

54

Full load
(measured at a
distance of 1 m)

[dB(A)]

71

71

Idling (measured at
a distance of 4 m)

[dB(A)]

53

53

Full load
(measured at a
distance of 4 m)

[dB(A)]

67

67

Mineral oil DIN ISO 6743-4 for LUKAS hydraulic equipment and others

Oil temperature range

Oil code

Viscosity rating

Remarks

A

-20 .... +55°C

HM 10

VG 10

Oil temperature range

Oil code

Viscosity rating

Remarks

A

-4.0 .... +131°F

HM 10

VG 10

recommended viscosity range: 10...200 mm²/s

(10…200 cSt.)

Supplied with HM 10 DIN ISO 6743-4.

CAUTION!
Before you use hydraulic fl uids from a different manufacturer, you must contact
LUKAS or an authorised dealer.

12.3 Hydraulic fl uid recommendation