background image

17

4. Now insert the battery or the mains adapter into the unit (if not already fi tted). The mains

adapter must then be connected to the power supply.

5. The hydraulic unit must now be bled. This takes place fully automatically on the P600OE.

To carry out bleeding you just have to switch the hydraulic pump on at the main switch and
let it run for two to three minutes without having a unit connected to it.

The

fi ller cap is also fi tted with a vent which automatically bleeds the tank when the pump

is running.

6. After bleeding, check the level of fl uid in the tank again. Top up if necessary.
7. Finally, you can now connect the extension hoses or hose reels and/or connect the rescue

equipment directly.

7.1 Operating the P600OE

7. Operation

The P600OE has been designed to provide the user with the simplest method of operation.
For this reason, the pump only needs to be switched on and off and the rescue unit be con-
nected to it. All the other functions are carried out fully automatically.

However, always connect the rescue unit before switching the hydraulic unit on. After switch-
ing on, the initiation sequence on the unit is run. This takes approx. 3 seconds. During this
period the LED in the main switch fl ashes and the motor runs for approx. 1.5 secs. in ECO
mode and approx. 1.5 secs. in working mode. As soon as the LED lights up permanently in
the main switch you can start working with the connected rescue equipment. If the connected
unit is not actuated, the unit switches back to the ECO mode after a few seconds.

CAUTION!
If a rescue unit is actuated during the initiation sequence, the pump could
inadvertently switch to the ECO mode during operation. To restore full functionality
switch the pump off, switch it on again and allow the initiation sequence to run
as described above.