Fault

Check

Cause

Solution

Connected rescue
device does not
reach its specifi c
performance data

Maximum permitted
operating pressure of
the pump is not reached

Have repaired by
authorised service
facility, authorised
dealer or directly by
LUKAS

Connected unit
defective

Rectifi cation see
operating instructions of
the connected unit

During function test:
A pressure gauge
installed between the
rescue equipment
and the hydraulic
power pack does
not indicate the
maximum operating
pressure of the
equipment.

Check the details
of the rescue
device

The operating pressure
of the connected
rescue device is locked
internally

No repair or fault
rectifi cation required

Connected rescue
device is defective

Rectifi cation see
operating instructions of
the connected unit

Hydraulic unit defective

Have repaired by
authorised service
facility, authorised
dealer or directly by
LUKAS

Maximum pressure
not achieved

Mono-coupling on
connection hose is
defective

Replace connection
hose

Hydraulic unit defective

Have repaired by
authorised service
facility, authorised
dealer or directly by
LUKAS