Troubleshooting – Lukas P 600 OE User Manual

Page 26

Advertising
background image

26

11. Troubleshooting

Fault

Check

Cause

Solution

The PO600OE
switches
inadvertently to the
Eco mode when
working with a
rescue unit

The initiation sequence
period of 3 seconds
is not allowed to be
carried out

Switch the pump off
and on again. Use the
rescue unit only after
the initiation sequence
has been fully carried
out. Flashing light
in the on/off switch
goes to permanent
light (see also
Paragraph 7.1)

Electric motor does
not start following
activation of the
main switch

Battery or mains
unit positioned
correctly in the
connection slot
and locked in
position

Battery or mains unit
not inserted properly

Remove the battery
or mains unit from the
pump and re-insert.

Check connection
of mains unit

Mains unit cable not
connected

Connect mains unit
cable to the power
supply

Correct battery
fi tted?

Incorrect battery

Use stipulated battery

Battery fl at

Charge battery

Battery or mains unit
defective

Use a different battery
or mains unit.

Fault in power supply to
the mains unit

Troubleshooting the
power supply

Use a different power
supply

P600OE defective

Shut down immediately
and have repaired by
authorised service
facility, authorised
dealer or directly by
LUKAS

Advertising