Pressure filter, Pressure filter -23, Pressure filter removal -23 – JLG 80SL Service Manual User Manual

Page 59

Advertising
background image

SECTION 3 - CHASSIS, PLATFORM & SCISSOR ARMS

3121325

– JLG Lift –

3-23

Pressure Filter

Removal:

1. Disconnect hose(s) from the Pressure Filter (1).

2. Loosen and remove the four Capscrews (2) and

Lockwashers (3).

3. Remove the Pressure Filter.

NOTE: Replace filter every 250 hours of operation.

Installation:

1. Align the pressure filter so that the screw holes

match up with the screw holes on the holding
bracket.

NOTE: Be sure arrow on top of filter points towards the

hydraulic tank.

2. Insert the four Lockwashers and Capscrews into the

holes and tighten.

3. Reconnect any hose(s) disconnected during

removal.

1

2, 3

1. Pressure Filter

2. Capscrew, M10 x 20mm

3. Lockwasher, M10

Figure 3-21. Pressure Filter Removal