SECTION 2 - PREPARATION AND INSPECTION

1-877-254-3876

LIFTPOD by JLG

1001070451

1-877-2-LIFTPOD

www.liftpod.com

2-7

legible; emergency stop switch reset for operation; con-
trol markings legible. Battery is installed and secure.

10. Platform Assembly and Gate - Check mounting pins

are not loose; platform railing is undamaged; platform
latch is engaged on carriage (Figure 2-7.); self-closing
entry gates are in proper working order; no cracks or
corrosion visible.

11. Tool Tray - See next page for Tool Tray Pre-Start Inspec-

tion Procedure.

Figure 2-4. Examples of new, acceptable and

unacceptable ropes

Figure 2-5. Ropes retained in mast cap

Figure 2-6. Rope anchor points

Check both ropes
are retained in

groove in cap

Mast

Mast Cap

Check that each termination is
engaged under its anchor point
by viewing through the cover.

The two upper rope tails

should be slack.

The lower rope loop should
be tight around anchor.